Factbites
 Where results make sense
About us   |   Why use us?   |   Reviews   |   PR   |   Contact us  

Topic: EIA interface


Related Topics
PAL

In the News (Sun 6 Dec 09)

  
  Operator Interface News - QSI Corporation
The terminal is available with an EIA-232, -422 or 5 volt buffered serial interface; a Supertwist 20x4 LCD display with lighted or VFD display options; and an 18-, 24, or 40-key customizable keypad.
QSI Corporation, manufacturer of rugged operator interface and mobile data terminals, has recently published the white paper, "Operator Interface Buyer's Guide".
Human-machine interface terminals used in rugged environments require specific technology for optimum performance.
qsicorp.blogspot.com   (2793 words)

  
  Interface Design Description (IDD)
Interfaces involving optional elements are not required until the option for the element is exercised; however, a contractor should provide a design with built-in flexibility to support the subsequent inclusion of these optional elements in order to minimize the overall system cost associated with system upgrades.
This is a functional interface that consists of two physical interfaces: an interface between the IDM and the DII and an interface between the SBM and the DII.
The electrical and physical characteristics of the interface shall be as specified for the RT to RBM interface in section 3.23.3.
www.globalsecurity.org /space/library/report/1997/irs2_5.htm   (12317 words)

  
 100 Base-T to Fiber Converter
The Model 62-1 is designed to interface to an RS-232 port configured as a DTE which converts the EIA-530 port to DTE.
The Category-I circuits of the EIA-530 interface are electrically equivalent to RS-422, a dual-differential protocol.
Of the two EIA signals associated with a circuit, the one referred to as the A signal is identified as TDA.
www.telebytedatacom.com /catalog/manuals/m62-2.htm   (1723 words)

  
 Telebyte Model 267-3/4 - Card Mounted EIA-530 to RS-232 Interface Converter
The Model 267-3/4 is a modular interface converter that accomplishes the hardware conversion between an RS-232 interface and an EIA-530 interface implemented in RS-422 and RS-423 voltage levels.
The Model 267 interface converter is a card that includes all of the circuitry to do bi-directional conversion for 10 Category I, differential drivers and receivers, and three Category II, single ended, circuits.
For the Model 267-3 the RS-232 port is configured to interface to a DTE and the EIA-530 port interfaces with a DCE.
www.bomara.com /Telebyte/catalog/products/267-34.htm   (266 words)

  
 Definition: eia interface   (Site not responding. Last check: )
EIA interface: Any of a number of equipment interfaces compliant with voluntary industry standards developed by the Electronic Industries Association (EIA) to define interface parameters.
Note 1: Some of the EIA interface standards have been adopted by the Federal Government as Federal Standards or Federal Information Processing Standards.
Note 2: The telecommunication-standards-developing bodies of the EIA are now part of the Telecommunications Industry Association (TIA), and the standards are designated TIA/EIA-XXX.
www.atis.org /tg2k/_eia_interface.html   (108 words)

  
 Cisco - Field Notice: ONS 15454: Electrical Interface Assembly (EIA) Connector Issue
A number of EIA Interface (I/F) assemblies have been manufactured with one or more 60-pin back plane connectors (ID P1-P12) rotated 180 degrees, resulting in installation and/or operational difficulties.
These connectors are symmetrical with the exception of a pair of index pins protruding from the center edges of the connector, one of which is slightly (.025") wider than the other.
Confirm that the LOS alarm indication is cleared, and that an AIS alarm is indicated for the port.
www.cisco.com /warp/public/770/fn13914.shtml   (726 words)

  
 Gesytec GmbH - Products - Easylon Interface Features
VNI stands for Virtual Network Interface and refers to the separation of the interface into a physical and a logical part.
With respect to a typical Easylon VNI Interface card for a PC this means that the card implements protocol layers 1 and 2 of the interface and the PC realizes layers 3 to 5.
Interface running MIP firmware can be used for all other applications, e.g.
www.gesytec.de /englisch/products/easylon/interface-features.htm   (945 words)

  
 IDS Interface Modules
Interface modules are are easily and quickly attached to the Model 77 base unit with a thumbscrew.
The RS-232-C Interface Module plugs into an IDS Model 77 Bit Error Rate Test Set and provides the interface to connect to a RS-232-C DCE, such as a Modem or Mux.
The V.35 Interface Module plugs into an IDS Model 77 Bit Error Rate Test Set and provides the interface to connect to a V.35 DCE, such as a Modem, DSU, or Mux.
www.idsdata.com /int7677.htm   (2146 words)

  
 Superverter® RS-422/RS-485 to RS-232 Interface Converter
Data equipment may employ another interface because it is more appropriate for the communication architecture being used or for the interference/noise environment within which communications must take place.
Besides doing straight forward interface conversion when needed, the Model 285 can even give you further flexibility in configuring your premises data communications network and allow you to 'make do' with data equipment that may not be exactly suited to your needs, but which are available.
After some period of time the laboratory manager decided that for his installation a network was needed where a minicomputer would control a plotter and communicate with two terminals.
www.telebyteusa.com /catalog/appnotes/a285.htm?Te   (676 words)

  
 The Electrodata ITS 5 Interface Test Set   (Site not responding. Last check: )
It permits interface signals to be monitored and generated to help isolate and identify sources of trouble.
Indicators allow monitoring of all 25 lines on each side of the interface for the presence of high, low or alternating voltage levels, or the absence of a signal altogether.
Breakout pins and jumpers provide access to all lines of the interface, and switches allow any of the 25 circuits to be "made" or "broken".
www.electrodata.com /its5.htm   (168 words)

  
 UARTs, Modems, Cards   (Site not responding. Last check: )
EIA RS-232 - An ancient standard for the connection of teletypes and computers to modems.
It also provides signals to control a modem through operations such as "hang up the phone." There are many EIA standards, but this is the most famous.
When the "EIA interface" is discussed without any particular standard being referenced, then the RS-232 interface is almost certainly the topic.
www.yale.edu /pclt/COMISDN/UART.HTM   (529 words)

  
 Capital Currents - 10/1/2000 - CED - CA6253370   (Site not responding. Last check: )
Now we are looking at two contenders for a digital baseband interface with a data rate high enough to carry uncompressed HDTV from a set-top box to a display.
So attention shifted to a baseband interface, in particular IEEE 1394, also known as "Firewire." But 1394 is insufficient because it is merely a physical layer specification, and a command language was needed so that the set-top box and TV set could talk to one another.
Adding another interface, using a different connector, and supporting different capabilities is not necessarily a step toward marketplace success.
www.cedmagazine.com /article/CA6253370.html   (858 words)

  
 Data Transmission Overview Page
Previously, EIA labeled the standards with the prefix "RS", which stood for recommended standard.
TIA/EIA-422-B was defined by the EIA for high-speed data transmission in rugged environments.
This electrical standard generically known as LVDS (Low Voltage Differential Signaling) provides all the benefits of differential data transmission and is capable of operating at data rates in excess of 655 Mbps.
www.national.com /appinfo/interface/0,1801,128,00.html   (637 words)

  
 Gesytec GmbH - Products - Easylon IP Interface for LonWorks
Drivers for this interface provide the same functionality as other Easylon interfaces, thus enabling all applications operation with standard interfaces for LON over IP.
The Easylon IP Interface operates as a VNI interface.
The interface is, of course, compatible with all LON/IP routers.
www.gesytec.de /englisch/products/easylon/el_ip-interface.htm   (185 words)

  
 RS232 Tutorial on Data Interface and cables
The RS-232 interface presupposes a common ground between the DTE and DCE.
The number of output lines, the type of interface driver IC, and the state of the output lines are important considerations.
Is Your Interface a DTE or a DCE?
www.arcelect.com /rs232.htm   (2828 words)

  
 Radyne - TRS1 1:1 Redundancy Protection Switch   (Site not responding. Last check: )
The TRS1 is a two-input, one-output redundancy protection switch that monitors the status of the primary network interface device.
This device might be a modulator, interface adapter, encryption unit, PSIP generator, etc. It automatically substitutes a spare upon detecting a failure of the primary chain.
Use of either control interface is optional, and TRS1 will continue to provide automatic switching in the event of failure of the on-board microprocessor.
www.radynecomstream.com /doc/trs1.html   (238 words)

  
 RS-232 and other serial ports and interfaces pinouts listing @ pinouts.ru
RS-232 (EIA-232) serial interface pinout RS-232 is the standard serial communications interface found on all types of equipment such as computers, modems, printers, Microcontrollers, eprom programmers, and a host of other devices.
The EIA describes RS422 as a DTE to DCE interface for point-to-point connections.
RS-530 (EIA530) interface pinout EIA-530, or RS-530, is a balanced serial interface standard that generally uses a 25 pin connector.
pinouts.ru /pin_SerialPorts.shtml   (804 words)

  
 Electronics Industry Association
The EIA is a member based, not for profit organisation, representing electronics and related business companies primarily in South Australia.
The EIA staff pride themselves on excellenct customer service and events and information that are second to none.
Contact any EIA staff member for information as everyone is equipped to answer questions about the electronics industry and or the EIA. However if you're contacting the EIA for the first time and would like to make sure you contact the correct person, here is a short outline of who does what at the EIA:
www.eiaa.asn.au   (443 words)

  
 B.6. Subnetwork-type dependent requirements.   (Site not responding. Last check: )
Two optional interfaces are specified in 6.3.1.1 and 6.3.1.2 of the Profile.
The EIA-366-A dialing interface is not permitted to be physically or electrically connected during classified operation.
One synchronous EIA-449 interface for each attachment port shall be provided on the MCU to provide the capability to connect to a cryptographic device.
www.dtic.mil /ieb_cctwg/contrib-docs/VTC001/annx-b6.html   (337 words)

  
 Video Buses, Video Bus Descriptions, Video Pinout
Serial digital interface [SDI] standard is based on a 270 Mbps transfer rate, over a single 75 ohm coaxial cable, up to 600 feet.
Serial Digital Interface is a digital broadcast television standard providing digital encoding of standard NTSC and PAL formats, with embedded audio.
However Y/C is the correct term, but the term S-Video is widely used to indicate the interface when in fact refers to a VCR tape format.
www.interfacebus.com /Design_Connector_Video.html   (881 words)

  
 EIA-422 - Wikipedia, the free encyclopedia
The current title of the standard is TIA-422 Electrical Characteristics of Balanced Voltage Differential Interface Circuits and is now in revision B, published in May 1994, and was reaffirmed by the Telecommunications Industry Association in 2005.
The mechanical connections for this interface are specified by EIA-530 (DB-25 connector) or EIA-449 (DC-37 connector), however devices exist which have 4 screw-posts to implement the transmit and receive pair only.
Also, an RS-232-compatible variant of RS-422 using a mini-DIN-8 connector was widely used on Macintosh hardware until it was replaced by Intel's Universal Serial Bus on the iMac in 1998.
en.wikipedia.org /wiki/EIA-422   (461 words)

  
 VT100.net: LA100-Series Programmer Reference Manual
The EIA interface connector is a DB-25 male 25 pin connector mounted on the back of the terminal (Figure 1-2).
NOTE: The 20 mA current loop interface option allows the terminal to be connected directly to a computer up to 305 m (1000 ft) away without the use of a modem.
The EIA interface or optional 20mA current loop interface can be used in both applications.
vt100.net /docs/la100-rm/chapter1.html   (2158 words)

  
 AIM User's Manual, Part I: Hardware Installation - Overview
The individual ports are derived by using cable assemblies or a distribution panel.
Interface cards are available with a variety of interface protocols such as OSI, TBOS, E2A, and others.
Is an EIA-232 interface that can be used for configuration and diagnostic output from the common logic/interface card.
www.aiinet.com /documents/html/Aim/M/0/aimch2.htm   (802 words)

  
 QSI Corporation - Rugged Operator Interface and Human Machine Interface (HMI) Terminals
Our rugged human machine interfaces (HMIs) are available in a variety of customizable configurations, and are built to withstand a wide range of environmental conditions.
EIA-232 -422 or 5-volt Buffered interface, supertwist 20×4 LCD display, 24- or 40-key programmable keypad, CE certified.
EIA-232, -422, -485 or 5-volt Buffered interface, supertwist 20×4 LCD display, 24- or 40-key keypad, handheld housing with battery back, CE certified.
www.qsicorp.com /product/industrial   (391 words)

  
 EDT Products -- PCI CD-60
The device interface uses EIA-644 Low Voltage Differential Signals (LVDS) compatible driver/receivers connected to a RAM based programmable gate array and 4 KByte FlFOs.
That is, all data and control signals are sampled with a clock transmitted along with the data and control signals.
This clock may be generated by the DMA interface or the user device or both.
www.edt.com /pcicd60.html   (332 words)

  
 eia Info Page
To see the collection of prior postings to the list, visit the eia Archives.
Subscribe to eia by filling out the following form.
You will be sent email requesting confirmation, to prevent others from gratuitously subscribing you.
lists.ellipsis.cx /mailman/listinfo/eia   (251 words)

  
 EIA interface monitor and breakout panel model 60   (Site not responding. Last check: )
EIA interface monitor and breakout panel model 60
EIA interface monitor and breakout panel model 60 - $10
EIA Interface Monitor and Breakout Panel Model 60, call me anytime 972-835-9595
dallas.craigslist.org /tls/250029454.html   (88 words)

  
 EIA interface - Wikipedia, the free encyclopedia
EIA interface is the term for a number of equipment interfaces compliant with voluntary industry standards developed by the Electronic Industries Association to define interface parameters.
The telecommunication standard developing bodies of the EIA are now part of the Telecommunications Industry Association, and the standards are designated TIA/EIA-XXX.
This article related to telecommunications is a stub.
en.wikipedia.org /wiki/EIA_interface   (96 words)

  
 RS232 to EIA 530 Interface Converter -Telebyte Models 62-1 62-2
These devices provide conversion for the entire EIA-530 interface which includes ten Category I circuits and three Category II circuits.
The 62-2 is designed to interface to a DCE RS-232 port.
The electrical interface of the EIA-530 port fully complies with RS-422.
www.telebyteusa.com /catalog/products/62-12.htm   (159 words)

  
 RS232 to RS485
Interface Powered, RS-232 (EIA-574) to RS-485 Interface Converter (with Handshaking)
The Model 2089 is Patton’s first high speed EIA-574 (RS-232 on a DB-9) to RS-485 interface converter.
Supporting async data rates to 115.2 kbps over one or two unconditioned twisted pair, the Model 2089 passes one control signal in each direction.
www.dceexpress.com /Patton_2089_RS.htm   (271 words)

  
 E1 G.703 - EIA-530 2.048Mbps, X.21 or V.35 DTE Interface Converter : DC2000
The DC2000 enables the connection of an E1 G.703 2 Mbps leased line to DTE equipment such as a router presenting an EIA-530, V.35 or X.21 interface.
Data is carried on the E1 line as unstructured payload.
In addition to providing very cost-effective interfacing, the DC2000 provides a test and troubleshooting facility with Remote loop and Local loop test functions as well as a Remotely activated loop test which often eliminates the need for an engineer to visit a remote site for diagnosis of problems.
www.metrodata.co.uk /products/datasheets/dc2000-e1-converter.htm   (188 words)

  
 QSI Corporation - QTERM®-G70 - Ethernet-enabled, color graphic operator interface terminal with touch screen.
The QTERM-G70 is an Ethernet-enabled, graphic human machine interface (HMI) terminal with Qlarity® object-based programming.
Qlarity (pronounced "Clarity") is an object-based programming language designed by QSI Corporation for our intelligent graphic operator interface terminals.
Real-world applications where Qlarity and the QTERM-G70 operator interface terminal are being used.
www.qsicorp.com /product/industrial/qterm-g70.php   (539 words)

Try your search on: Qwika (all wikis)

Factbites
  About us   |   Why use us?   |   Reviews   |   Press   |   Contact us  
Copyright © 2005-2007 www.factbites.com Usage implies agreement with terms.